Uninterruptible Power Supplies   UPS Systems (100 - 800kVA)
----------------------------------------------------------------------------------------------------------------------------------------
 
  500va to 10kVA
Comms rack and tower UPS models for small sized applications >
 
    Starlet M 100 & 120kVA NEW!

Performance Input THDi <3% Input PF >0.99

Features Online double conversion with transformer-less inverter, power factor corrected input, integral static and manual bypass, auto-battery test, compact
footprint with 'back to wall' installation, dual input (configurable), backfeed protection, auto-configuration parallel capability (6 units max), 2 x DB9 serial ports for BMS,
2 x comms slots


Options
Maintenance bypass panel, isolation transformer, temperature compensated charger, parallel cards (6 units max), alarm card (240V), remote panel, SNMP card


Datasheet | Remote Panel | Network Monitoring
| Options
-------------------------------------------
  10 to 80kVA
Single and three phase UPS models for medium sized applications >
-------------------------------------------
  100 to 800kVA
Large UPS models
to cater for whole floors or entire buildings >
-------------------------------------------------------------------------------------------------------------------------------------
  Sirius P 100 - 250kVA (300 & 400kVA available 2010)

Performance Input THDi <4% Input PF >0.99

Features
Online double conversion with inverter output transformer, power factor corrected input, integral static and manual bypass, auto-battery test, compact footprint with 'back to wall' installation, dual input (configurable), backfeed protection, auto-configuration parallel capability (up to 6 units),
2 x DB9 serial ports for BMS, 2 x comms slots

Options
Maintenance bypass panel, parallel card (6 units max), bypass isolation transformer,
temperature compensated charger, top entry cable chamber, contact card (240V), fan failure alarm, remote panel, SNMP card,
UGS
(Synchronised outputs)

Datasheet | Remote Panel | Network Monitoring
|
Options
  Service Agreements
24-7 callout,
preventative
maintenance,
spare parts
 
  Delivery & Associated Services
-------------------------------------------
Site Surveys and Pre Sales
-------------------------------------------
Low Voltage Switchgear 
-------------------------------------------

Diesel Generator Sets
-------------------------------------------
Central Battery Systems
-------------------------------------------
UPS Network Monitoring
-------------------------------------------------------------------------------------------------------------------------------------
  Sirius 100 - 800kVA

Performance Options
6 Pulse (100-120), 12 Pulse & 12 Pulse with Filter (100-800)

Features Online double conversion with full galvanic isolation, static and manual bypass, dual input (configurable), automatic battery test, auto-configuration parallel capability (6 units max), backfeed protection, DB15 serial port for BMS, 2 x comms slots

Options Maintenance bypass panel, parallel card (6 units max) isolation transformer,
temperature compensated charger, top entry cable chamber, contact card (240V), fan failure alarm, remote panel, SNMP card, UGS (Synchronised outputs)

Datasheet | Remote Panel | Network Monitoring |
Options
 
-------------------------------------------------------------------------------------------------------------------------------------
   